Cloison siphoïde flottante testée sur banc d'essai retenant des macro-déchets flottants
Floating siphon barrier tested on a test bench to trap floating macro-debris
3D EAU product

Trapping floating macro-debris using a movable siphon barrier

A mechanical device that operates without electricity and monitors the water level in the system to trap oil, plastic, and floating debris before they reach the natural environment.

The challenge

How can we prevent floating waste collected by sewer systems from entering the natural environment?

Especially during rainy periods, sewer and stormwater systems can carry floating macro-waste, which sometimes ends up in the receiving environment.

The 3D EAU solution

The Floating Siphon Partition

Installing a siphon wall prevents this pollution of the receiving environment. The wall blocks surface flow, forcing the water to pass through the siphon. The goal is to prevent oils, plastic waste, and all other floating materials from being carried into the natural environment without treatment.

Utilisation d’une cloison siphoïde mobile qui suit mécaniquement le niveau d’eau afin de retenir les flottants.
Operating Principle of a Siphon Barrier Upstream of a combined sewer overflow

Unlike a fixed siphon wall, the movable siphon wall can rest very close to the pipe’s foundation during dry weather. Its gradual rise as the water level rises, along with its velocity-reducing design, allows it to retain as many floating debris as possible upstream.

Mise en ouvre du piege a  flottant
Implementation Example—Downstream View
mise en oeuvre d'un piège à flottant
Implementation example—view from upstream

Video showing the product in action

Manufacturing and installation

The movable siphon partition is custom-designed and manufactured from 316L stainless steel in our workshops in France.

3D EAU tests it on a test bench to verify its hydraulic performance. It is then delivered to the site for installation.

Installation is trenchless and takes just a few days, requiring minimal civil engineering work. The partition is lowered through the existing access manhole and installed in the pipeline system.

Benefits

1

A mechanical system that does not require a power supply

2

No impact on day-to-day operations.

3

Limited impact on the structure’s drainage capacity during storm events

A question · an information · a quote

Let's talk about your network configuration

Our team of hydraulic engineers will help you find the solution best suited to your site.